NOTICE
The function of the EP terminals is only available when Safety Integrated Basic Functions
are enabled.
5.6.3.3

X46 Brake control and monitoring

Table 5- 34
Terminal strip X46 brake control and monitoring
Terminal
1
2
3
4
Max. connectable cross-section 1.5 mm
CAUTION
The length of the connecting lead at terminal strip -X46 must not exceed 10 m, and the lead
must not be brought out outside the control cabinet or control cabinet group.
Cabinet Modules
Manual, (GH5), 05/2010, A5E03263538A
Function
BR output +
BR output -
FB input +
FB input -
2
Technical data
This interface is intended for the connection of the Safe Brake
Adapter.
Cabinet Modules
5.6 Chassis format Motor Modules
197

Hide quick links:

Advertisement

Table of Contents