Siemens SINAMICS S120 Manual page 394

Modular motion control drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Options
8.18 L07, dv/dt filter compact plus Voltage Peak Limiter
When a dv/dt filter compact is used, the pulse frequency of the Motor Module must not
exceed 2.5 kHz or 4 kHz. If a higher pulse frequency is set, then this could destroy the dv/dt
filter.
Note
It is permissible to set pulse frequencies in the range between the rated pulse frequency and
the relevant maximum pulse frequency when a dv/dt filter compact plus Voltage Peak Limiter
is used.
Table 8- 32
Max. pulse frequency when a dv/dt filter compact plus VPL is used in units with a rated
pulse frequency of 2 kHz
Order no.
6SL3720-...
1TE32-1AAx
1TE32-6AAx
1TE33-1AAx
1TE33-8AAx
1TE35-0AAx
394
WARNING
Unit rating [kW]
pulse frequency of 2 kHz [A]
Line voltage 380 – 480 V 3 AC
(DC link voltage 510 - 750 V DC)
110
132
160
200
250
Output current for a
210
260
310
380
490
Max. pulse frequency when a dv/dt filter is
used
4 kHz
4 kHz
4 kHz
4 kHz
4 kHz
Manual, (GH5), 05/2010, A5E03263538A