Cabinet Modules
5.6 Chassis format Motor Modules
Order no.
Dimensions (standard version, IP20)
- Width
8)
- Height
9)
- Depth
Weight, approx. (standard version)
Frame size
Rated output of a typ. 6-pole standard induction motor based on I
1)
Rated output of a typ. 6-pole standard induction motor based on I
2)
The base load current I
3)
The base load current I
4)
For the interdependency of pulse frequency and max. output current/output frequency, see SINAMICS - Low-Voltage
5)
Configuration Manual on the customer DVD supplied with the device.
The specified power loss equals the maximum value at 100 % capacity utilization. The value in normal operation is
6)
lower.
Total of all motor cables. Longer cable lengths for specific configurations are available on request, see SINAMICS -
7)
Low-Voltage Configuration Manual on the customer DVD supplied with the device.
With option L08 (motor reactor):
8)
- Frame size HX/JX →Supplementary cabinet 600 mm wide
With option L10 (dv/dt filter plus VPL):
- Frame size FX/GX/HX/JX →Supplementary cabinet 600 mm wide
With option L34 (circuit breaker at output side):
- Frame size FX/GX →Supplementary cabinet 400 mm wide
- Frame size HX/JX →Supplementary cabinet 600 mm wide.
The cabinet height increases by 250 mm with IP21 degree of protection, and by 400 mm with IP23, IP43 and IP54
9)
degrees of protection.
5.6.6

Overload capability

The Motor Modules in the chassis format are equipped with an overload reserve to handle
breakaway torques, for example.
In the case of drives with overload requirements, the appropriate base load current must,
therefore, be used as a basis for the required load.
For overload, the following precondition applies: The drive is operated with its base load
current before and after the overload occurs (a duty cycle duration of 300 s is used as a
basis here).
208
6SL3720-
mm
mm
mm
kg
is based on a duty cycle of 110% for 60 s or 150% for 10 s with a duty cycle duration of 300 s.
L
is based on a duty cycle of 150% for 60 s or 160% for 10 s with a duty cycle duration of 300 s.
H
1TG37-
1TG38-
1TG38-
4AA3
1AA3
8AA3
800
800
800
2200
2200
2200
600
600
600
700
700
700
JX
JX
JX
or I
at 3 AC 50 Hz 500 V or 690 V.
L
H
or I
at 3 AC 60 Hz 575 V.
L
H
Manual, (GH5), 05/2010, A5E03263538A
1TG41-
1TG41-
0AA3
3AA3
800
800
2200
2200
600
600
700
700
JX
JX
Cabinet Modules