ISSUE 3.01
5.
Dial the system password + Hold.
Refer to the following table for the default system passwords. To change the passwords, use
90-02 : Programming Password Setup on page
Password
User Name
******
nec-i
12345678
tech
0000
admin1
9999
admin2
S
4 HOW TO EXIT PROGRAMMING MODE
ECTION
To-exit the programming mode :
When you are done programming, you must be out of a program option to exit (pressing the Mute key
will exit the program option).
1.
Press Mute key to exit the program options, if needed.
2.
Press Speaker. If changes were to the system programming, "Saving System Data" is displayed.
3.
The display shows "Complete Data Save" when completed and exits the telephone to an idle
mode.
Programming Manual
2-549.
Program Mode
(SL1000)
Program Mode
Base Service OP1 OP2
(SL1100)
Level
1 (MF)
Manufacture Level (MF) :
80-02, 81-04, 81-05, 82-02 (SL1000), 82-05, 82-08 (SL1100)
2 (IN)
Installation (IN) :
All programs in this section not listed for MF, SA, & SB
3 (SA)
System Administrator - Level 1 (SA) :
10-01, 10-02, 10-12, 10-13, 10-14, 10-15, 10-16, 10-17, 10-18, 10-23,
10-24, 10-25, 10-28, 10-29, 10-45, 12-02, 12-03, 12-04, 12-08, 15-01,
15-07, 15-09, 15-10, 15-11, 20-16, 20-34, 21-07, 21-14, 22-04, 22-11,
22-17, 25-08, 30-03, 30-04, 32-02, 45-02, 84-22, 90-03, 90-04, 90-06,
90-07, 90-19, 90-57, 90-58, 90-59, 90-65
4 (SB)
System Administrator - Level 2 (SB) :
13-04, 13-05, 13-06, 13-11, 15-14 (SL1100), 21-20
Program Mode
(SL1000)
Program Mode
Base Service OP1 OP2
(SL1100)
Programs at this Level
SL1000/SL1100
1-3