Program 34 : Tie Line Setup; E&M Tie Line Basic Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 3.01
Level:
IN
Description
Use Program 34-01 : E&M Tie Line Basic Setup to define the basic settings for each E&M Tie line.
Input Data
Trunk Port Number
Item
Item
No.
01
DID/E&M Start
Signaling
02
Receive Dial
Type for E&M Tie
Line
03
E&M Dial-In
Mode
04
E&M Line Dial
Tone
05
System Toll Re-
striction
Conditions
None
Feature Cross Reference
None
Programming Manual

Program 34 : Tie Line Setup

34-01 : E&M Tie Line Basic Setup
Input Data
nd
Set the start signaling mode for DID
0 = 2
Dial Tone
and Tie trunks. DID and Tie trunks
1 = Wink
can use either immediate start or
2 = Immediate
wink start signaling.
3 = Delay
0 = DP
1 = DTMF
0 = Specify Extension
Determine if the incoming Tie Line
Number (Intercom)
call should be directed as an inter-
1 = Use Conversion
com call or if it should follow the DID
Table (NTT)
Translation Table in Program 22-11.
0 = Disable (No)
Enter 1 if the Tie Line should send
1 = Enable (Yes)
dial tone to the calling system after
the call is set up. Enter 0 if the Tie
Line should not send dial tone.
0 = System
Determine if an incoming Tie Line
1 = Each Extension
call should be subject to Toll Re-
striction. If it is set to 0 then it will
use the Program 21-05-13, if it is set
to 1 then it will used Programs
21-05-01 ~ 21-05-13.
001 ~ 126 (SL1000)
001 ~ 096 (SL1100)
Description
Default
SL1000/SL1100
Program
34
Related
Program
0
22-02
1
10-09
0
22-11
1
0
21-05
2-357