T1 Trunk Timer Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 3.01
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.
Input Data
Item
Item
No.
01
Answer Signal Detection Time
(Loop)
02
Answer Signal Detection Time
(Ground)
03
Answer Signal Detection Time
(DID)
04
Answer Signal Detection Time
(E&M)
05
Answer Signal Detection Time
(OPX)
06
Clear Signal Detection Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms)
07
Clear Signal Detection Time
(Ground)
08
Clear Signal Detection Time (DID)
09
Answer Signal Detection Time
(E&M)
10
Clear Signal Detection Time (OPX)
11
Ringing Signal Detection Time
(Loop)
12
Ringing Signal Detection Time
(Ground)
13
Ringing Signal Detection Time
(DID)
14
Ringing Signal Detection Time
(E&M)
15
Ringing Signal Detection Time
(OPX)
16
Ringing Signal Stop Detection
Time (Loop)
17
Ringing Signal Stop Detection
Time (Ground)
18
Ringing Signal Stop Detection
Time (DID)
19
Ringing Signal Stop Detection
Time (E&M)
Programming Manual

81-08 : T1 Trunk Timer Setup

Input Data
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 250 (4 ms ~ 1000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 250 (8 ms ~ 2000 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
1 ~ 255 (100 ms ~ 25500 ms)
SL1000/SL1100
Program
81
Default
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
15 (60 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
6 (600 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
10 (80 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
50 (5000 ms)
2-483

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents