Program 23 : Answer Features Setup; Call Pickup Groups - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Level:
IN
Description
Use Program 23-02 : Call Pickup Groups to assign extensions to Call Pickup Groups. This program
Program
also lets you assign an extension Call Pickup Group priority. If two extensions in a group are ringing at
the same time, Group Call Pickup intercepts the highest priority extension first.
23
There are 32 available Call Pickup Groups.
Input Data
Item
No.
01
Priority
Conditions
None
Feature Cross Reference
• Group Call Pickup
2-290

Program 23 : Answer Features Setup

Extension Number
Group Number
Item
Input Data
1 ~ 999

23-02 : Call Pickup Groups

Maximum four digits (SL1000)
Maximum eight digits (SL1100)
Description
Use this program to assign exten-
sions to Call Pickup Groups other
than the extension group set up by a
Program 16-02.
Program 23 : Answer Features Setup
ISSUE 3.01
1 ~ 32
Default
Related
Program
1 - xxx
11-12-26
(Note; default
11-12-27
value follows the
11-12-28
port order of
15-07-24
PRG11-02 or
15-07-25
PRG11-04.)
15-07-26