Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID
feature.
Input Data
Item
Item
No.
01
Caller ID Displaying
Format
02
Caller ID Wait Timer
03
Caller ID Edit Mode
04
Wait Facility IE Timer
05
Caller ID Sender
Queuing Time (Send-
er Wait)
07
Long Distance Code
08
Area Code
Conditions
None
Feature Cross Reference
• Caller ID
Programming Manual
Program 20 : System Option Setup

20-19 : System Options for Caller ID

Input Data
0 = First 10 digits (Up-
(if displaying digits are more than 12 digits)
per)
1 = Last 10 digits (Low-
er)
0 ~ 30 seconds
When an incoming CO call is received, the
SL1000/SL1100 starts the timer. It will wait
the programmed time for Caller ID infor-
mation from Telco before connecting the
CO call.
0 = Off
If Caller ID Edit Mode is disabled (0), no
1 = On
access code will be added to the Caller ID.
If this option is enabled (1), the access
code entered in PRG 10-02-02 & 10-02-03
will be added to the beginning of the Caller
ID.
0 ~ 64800 seconds
This timer is used with ISDN trunks to de-
termine how long the system waits for the
Caller ID name from the Telco.
0 ~ 64800 seconds
Up to two digits
Up to six digits
SL1000/SL1100
Description
Program
20
Default
0
5
0
10
0
No Setting
No Setting