ISSUE 3.01
Alarm
Re-
Type
Name
No.
port
63
0
0
SIP-MLT
trouble in-
formation.
64
1
0
VoIPDB
LAN Link
Error.
65
0
0
VOIPDB
trouble in-
formation.
66
2
0
SIP ex-
tension
License
Error.
67
0
0
SIP illegal
Packet
received
68
2
0
VoIPDB
DSP All
Busy
Alarm
Conditions
• The entire terminal that has an Alarm Display setting can be set at Program 90-50-01.
• System Alarm Type is shown despite the setting done at 90-10-01. If multiple Alarm Display Setting
is set, only one highest priority alarm will be shown on a LCD Display.
• The priority level (highest -> lowest) : Alarm 55 > Alarm 7 > Alarm 5 > Alarm 30 > Alarm 8 > Alarm
52> Alarm 29 > Free Demo License Period.
Programming Manual
Content of
Cause
Alarm
1.
The trouble
1.
The packet
occurred by
loss occurred
the SIP-
on the network
MLT rela-
or the wiring
tion.
cutting occur-
2.
The DSP
red.
resource
2.
DSP of
could not
VoIPDB not
be acquired
acquired.
at incom-
ing/outgo-
ing.
3.
The nego-
tiation with
VoIPDB
failed.
The link of LAN
1.
LAN cable is
of VoIPDB
defective.
came off.
2.
Connected
HUB broken.
3.
Defect CPU.
When DSP of
VoIPDB. Defective. 1.
VoIPDB notifies
Error.
More than the
• Wrong number
number of licen-
of licenses.
ses to which the
SIP extension
terminal was
turned on at
REGISTER.
The system re-
A client or network
ceived illegal
was illegal state.
packet.
1.
Provides
Not enough DSP
alert when
resources in sys-
all DSP re-
tem.
sources are
being used.
2.
Used to
trouble-
shoot or
alerting
when up-
grade is
needed.
SL1000/SL1100
Action
Recovery
Confirm whether
each equipment
such as wirings
and HUB is nor-
mal.
1.
Confirm LAN
When the
connector and
connection
wiring.
returns nor-
2.
Check with
mally, the er-
maker on un-
ror is recov-
certain points.
ered.
Possibility of
defective hard-
ware.
2.
Check with
maker on un-
certain points.
1.
Confirm the
When the
number of li-
number of
censes for SIP
registration of
extension ter-
SIP extension
minals.
terminals falls
2.
Check with
below the
maker on un-
number of li-
certain points.
censes.
Check with maker
on uncertain point,
when happening
frequently when
operating it.
Install VMDB with
more DSP resour-
ces.
Alarm
Status
WAR
Program
90
ERR
REC
WAR
WAR
INF
2-563

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100