Etu Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Level:
IN
Description
Use Program 10-03 : ETU Setup to setup and confirm the Basic Configuration data for each unit.
Program
When changing a defined terminal type, first set the type to 0 and then plug the new device in to have
the system automatically define it or you may have to reseat the unit.
10
The items highlighted in gray are read only and cannot be changed.
Input Data
For HBI PKG Setup (SL1000)
Item No.
01
02
03
04
05
06
For ESIU PKG Setup (SL1100)
2-4
Program 10 : System Configuration Setup
Slot No.
Physical Port Number
Item
Terminal Type
Logical Port Number
Transmit Gain level for SLT
Receive Gain level for SLT
Select port type
Multi-Line Telephone Line
Physical Port Number

10-03 : ETU Setup

00 ~ 16 (SL1000)
00 ~ 09 (SL1100)
01 ~ 08
Input Data
0 = No setting
1 = Multi-Line Telephone
2 = SLT
8 = Door Phone
10 = DSS Console
3 ~ 7, 9, 11, 12 = Not Used
1 ~ 128
1 ~ 63
(- 15.5 ~ + 15.5dB)
1 ~ 63
(- 15.5 ~ + 15.5dB)
0 = Hybrid Port
1 = Door Phone
0 = None
1 = 12 Line
2 = 24 Line
01 ~ 08
Program 10 : System Configuration Setup
ISSUE 3.01
Default
2
32
32
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents