Side Tone Auto Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 3.01
Level:
IN
Description
Note: This program is available only via telephone programming and not through PC Programming.
Use Program 90-68 : Side Tone Auto Setup to setup the volume level of Side Tone for each Analog
Trunk Port.
This program will change the setting of "PRG 81-07 CODEC Filter Setup for analog Trunk Port" If the
Analog Port is in used or if it is other than a Analog Trunk Port then it will give out the error message.
Input Data
Item
Item
No.
01
Adjustment Start Trunk Port Number
02
1 digit data
Conditions
None
Feature Cross Reference
None
Programming Manual
Program 90 : Maintenance Program
Input Data
This will start the Adjustment of Side
001 ~ 126 (SL1000)
Tone for each Analog Trunk Port. If
001 ~ 096 (SL1100)
it is successful it will change the
PRG 81-07. If it is successful it will
ask to change it for all Analog Trunk
Port.. If you select to change the
Setting All Analog Trunk Port it will
change all the Port in 81-07.
Dial (1 dight)
This setting will ask to use the digit
after Line is retrieved.

90-68 : Side Tone Auto Setup

Description
SL1000/SL1100
Default
Related
Program
No Setting
81-07-01
21-01-05
21-01-06
14-01-07
21-06-06
21-05-07
0
-
2-625
Program
90

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents