Service Tone Timers - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Level:
IN
Description
Use Program 20-18 : Service Tone Timers to set the values for the system service tone timers.
Program
Refer to the following chart for a description of each option, its range and default setting.
20
Input Data
Item
No.
01
Extension Dial
Tone Time
02
Busy Tone Timer 0 ~ 64800 seconds
03
Congestion Tone 0 ~ 64800 seconds
04
Call Waiting
Tone Timer
05
Multiline Confir-
mation Tone
06
Interval of Call
Waiting Tone
07
Intrusion Tone
Repeat Time
08
Conference Tone
Interval
09
Warning Beep
Tone Signaling
Interval
Conditions
None
Feature Cross Reference
• Distinctive Ringing, Tones, and Flash Patterns
2-206
Program 20 : System Option Setup
Item
Input Data
1 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
1 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds

20-18 : Service Tone Timers

Description
After getting Intercom dial tone, a
telephone user has this time to dial
the first digit of the Intercom call.
A Busy Tone when system resour-
ces run short. (Such as DTMF re-
ceiver resources).
This option sets the time between
Call Waiting tones. This timer also
sets the time between Off-Hook Sig-
naling alerts.
After a call is interrupted (such as
Barge-In, Voice Mail Conversation
Recording, or Voice Over), the sys-
tem repeats the Intrusion Tone after
this time. Normally, you should enter
0 to disable this time.
Program 20 : System Option Setup
ISSUE 3.01
Default
Related
Program
30
15
10
10
10
10
0
0
60
14-01-18