Mfc Tone Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Program 80 : Basic Hardware Setup for System
Level:
IN
Description
Use Program 80-08 : MFC Tone Setup to define the duration (On time) and pause (Off time) for MFC
Program
dialing. This option affects all trunk line calls system wide. And also it is possible to adjust the level of
tone.
80
Input Data
Item
No.
01
Duration (On time)
02
Pause (Off time)
03
Tone Level
Pause
Conditions
None
Feature Cross Reference
None
2-470
Item
1 ~ 255 (20 ms ~ 5100 ms)
1 ~ 255 (20 ms ~ 5100 ms)
1 ~ 97 (- 45 dB ~ + 3 dB)
Duration

80-08 : MFC Tone Setup

Input Data
Program 80 : Basic Hardware Setup for System
ISSUE 3.01
Default
5 (100 ms)
5 (100 ms)
77 (- 7 dB)

Hide quick links: