SL1000/SL1100
Level:
IN
Description
Program
Use Program 82-04 : ASTU Initial Data Setup to set the basic data of the SLT.
82
Input Data
Item
No.
01
Companding Method Type
02
Ringing Frequency
03
Minimum Break Time
04
Maximum Break Time
05
Minimum Make Time
06
Maximum Make Time
07
Minimum Hook Flash Time
08
Maximum Hook Flash Time
09
Minimum Ground Flash Time
10
Minimum Off-Hook Time
11
No Detection Time after Off-Hook
12
No Detection Time after Pulse Dial
Detection
13
Loop Disconnect Time, Reversal
Time
14
Ring, Message Wait Period Time
Conditions
None
Feature Cross Reference
None
2-494
Program 82 : Basic Hardware Setup for
Item
0 = μ-law
1 = A-law
0 = 25 Hz
1 = 20 Hz
2 = 16 Hz
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (5 ms ~ 1275 ms)
1 ~ 255 (10 ms ~ 2550 ms)
1 ~ 255 (5 ms ~ 1275 ms)

82-04 : ASTU Initial Data Setup

Input Data
Program 82 : Basic Hardware Setup for Extension
ISSUE 3.01
Extension
Default
1
0 (25 Hz)
2 (10 ms)
20 (100 ms)
2 (10 ms)
20 (100 ms)
108 (540 ms)
132 (660 ms)
21 (105 ms)
21 (105 ms)
60 (300 ms)
70 (350 ms)
60 (600 ms)
150 (750 ms)