Program 84 : Hardware Setup For Voipdb; H.323 Trunk Basic Information Setup - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

ISSUE 3.01

Program 84 : Hardware Setup for VoIPDB

Level:
IN
Description
Use Program 84-01 : H.323 Trunk Basic Information Setup to set the basic information of the H.323
Trunk.
Input Data
Item
Item
No.
02
Number of G.711 au-
dio frames
03
G.711 VAD mode
04
G.711 Type
05
Number of G.729 au-
dio frames
06
G.729 VAD mode
07
G.729 Jitter Buf-
fer( min)
08
G.729 Jitter Buffer
(average)
09
G.729 Jitter Buffer
(max)
11
Number of G.723 au-
dio frames
15
Jitter Buffer Mode
16
G.711 Jitter Buf-
fer( min)
17
G.711 Jitter Buffer
(average)
18
G.711 Jitter Buffer
(max)
19
G.723 Jitter Buf-
fer( min)
20
G.723 Jitter Buffer
(average)
21
G.723 Jitter Buffer
(max)
Programming Manual

84-01 : H.323 Trunk Basic Information Setup

Input Data
1 ~ 4
0 = Disable
1 = Enable
0 = A-law
1 = μ-law
1 ~ 6
0 = Disable
1 = Enable
0 ~ 300 ms
0 ~ 300 ms
0 ~ 300 ms
1 ~ 2
1 = Fixed
3 = Self adjusting
0 ~ 255 ms
0 ~ 255 ms
0 ~ 255 ms
0 ~ 300 ms
0 ~ 300 ms
0 ~ 300 ms
SL1000/SL1100
Description
Program
84
Default
3
0
0
3
0
30
60
120
1
3
30
60
120
30
60
120