System Alarm Setup; Table 2-20 Description Of Alarm - NEC SL 1000 Programming Manual

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You can designate
Program
an alarm as Major or Minor. This program also assigns whether or not the alarm information is
reported to the pre-defined destination.
90
Input Data
Item
No.
01
Alarm Type
02
Report
Alarm
Type
No.
1
2
2-558
Program 90 : Maintenance Program
Alarm Number
Item

Table 2-20 Description of Alarm

Re-
Content of
Name
port
Alarm
2
0
PKG Initi-
1.
The PKG
alize Er-
failed to ini-
ror.
tialize.
2.
The PKG
did not start
normally.
2
0
PKG
The unit did not
Mounting
step on a regu-
Error
lar procedure
and it was
pulled out.
Or, it is not nor-
mally inserted.

90-10 : System Alarm Setup

Input Data
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
1 = Report (autodial)
Cause
1.
PKG not inser-
1.
ted firmly.
2.
PKG was re-
2.
moved, but
not reinserted
3.
firmly.
3.
Old PKG data
still reported
due to no initi-
alization.
1.
The package
1.
is not com-
pletely inser-
ted.
2.
2.
The package
is out of order.
3.
Program 90 : Maintenance Program
ISSUE 3.01
001 ~ 100
Default
-
-
Action
Recovery
Insert PKG
During initiali-
firmly.
zation, the
Insert PKG
PKG is rec-
firmly.
ognized.
Delete slot in-
formation in
Program
90-05 and in-
sert the PKG
again.
Please insert
When unit is
the package
reconfirmed,
firmly.
the error is
Please try
recovered.
again after ini-
tializing the
system data
once when
LED doesn't
blink normally.
Exchange
packages.
Alarm
Status
ERR
REC
ERR
REC