SL1000/SL1100
Alarm
Type
No.
59
60
Program
90
61
2-562
Re-
Content of
Name
port
Alarm
2
0
Network-
Total number of
ing port
ports exceeded
limit ex-
the limit of 168
ceeded
ports in the net-
(V1.5
work.
Added)
2
0
SIP Reg-
1.
The regis-
istration
tration of
Error No-
the SIP
tification.
trunk to the
SIP server
failed.
2.
The regis-
tration of
the SIP
trunk to the
SIP server
failed in the
authentica-
tion.
3.
There is no
response
from the
SIP server
to the SIP
registration
request.
0
0
SIP ex-
1.
Failed reg-
tension
istration of
trouble in-
the SIP ex-
formation.
tension ter-
minal.
2.
The SIP ex-
tension ter-
minal was
not ac-
quired:
• At Regist of
the SIP exten-
sion terminal
to SL1000/
SL1100.
• When you
cannot ac-
quire the DSP
resource
when it sent.
Cause
Action
• New extension
Reduce extensions
or trunk ports
or trunks not to ex-
are added.
ceed 168 ports in
• A new system is
the network.
added in Pro-
gram 10-27-01.
• A new system is
connected to the
network.
• EXIFU is con-
nected.
1.
The setting of
1.
Confirm the
the system da-
following sys-
ta is wrong.
tem data set-
2.
The setting of
ting -- Pro-
the router is
grams 10-12,
wrong.
10-28, 10-29,
3.
It is an error to
10-30, and
the link of
10-36.
LAN.
2.
Confirm the
4.
Net side trou-
setting of rout-
ble.
ers.
3.
Confirm
whether ab-
normality oc-
curs on the net
side.
4.
Confirm the
authentication
system data
setting.
5.
Confirm wiring
and the sys-
tem data set-
ting. Please in-
quire on un-
certain points
of the maker.
1.
The registered
1.
Confirm wiring
port is used by
and the sys-
other exten-
tem data set-
sion.
ting.
2.
The license is
2.
Confirm
insufficient.
whether each
3.
DSP of
equipment
VoIPDB not
such as ac-
acquired.
cess points
works normal-
ly.
Program 90 : Maintenance Program
ISSUE 3.01
Alarm
Recovery
Status
When the to-
ERR
tal number of
ports be-
comes 168 or
less, the error
is recoverd.
The error is
ERR
recovered
REC
when normal-
ly connecting
it.
ERR
REC