Use Program 12-02 : Automatic Night Service Patterns to define the daily pattern of the Automatic
Mode Switching. Each Mode Group has 10 patterns. These patterns are used in Programs 12-03 and
12-04. The daily pattern consists of 20 timer Settings.
Input Data
Night Mode Service Group Number
Time Pattern Number
Set Time Number
Item
Item
No.
01
Start Time
02
End Time
03
Operation Mode
Example :
Time Pattern 1
0 :0 0
M o d e 3
(m id n ig h t)
To make the above schedule, it is necessary to set the data as follows:
Time setting 01 :
Time setting 02 :
Time setting 03 :
Time setting 04 :
Time setting 05 :
Time setting 06 :
Time setting 07 :
Time Pattern 2
00 : 00
Mode 2
(night)
Programming Manual
Program 12 : Night Mode Setup

12-02 : Automatic Night Service Patterns

0000 ~ 2359
0000 ~ 2359
1 ~ 8 = Night Modes 1 ~ 8
9 :0 0
1 2 :0 0
1 3 :0 0
M o d e 1
M o d e 4
M o d e 1
(d a y)
(re st)
(d a y)
00 : 00 to 09 : 00
09 : 00 to 12 : 00
12 : 00 to 13 : 00
13 : 00 to 17 : 00
17 : 00 to 18 : 00
18 : 00 to 22 : 00
22 : 00 to 00 : 00
00 : 00
01 ~ 04
01 ~ 10
01 ~ 20
Input Data
1 7 :0 0
1 8 :0 0
2 2 :0 0
M o d e 4
M o d e 2
M o d e 3
(re st)
(n ig h t)
(m id n ig h t)
Mode 3 (midnight)
Mode 1 (day)
Mode 4 (rest)
Mode 1 (day)
Mode 4 (rest)
Mode 2 (night)
Mode 3 (midnight)
SL1000/SL1100
Program
Default
Refer below
Refer below
Refer below
0 :0 0
2-93
12

Hide quick links: