NEC SL 1000 Programming Manual page 566

Hide thumbs Also See for SL 1000:
Table of Contents

Advertisement

SL1000/SL1100
Item
No.
08
TDM Echo Can-
celler Echo Type
09
TDM Max ERLE
(V2.0 Added)
Program
10
TDM Tx Level
Control
84
11
TDM Tx Level-
Control Level
12
TDM Tx Automa-
ticLevelControl
Level (V2.0 Add-
ed)
13
TDM Tx HLC
Threshold
14
TDM Tx Gain
Compression
mode
15
TDM Tx Gain
Compression
Threshold
16
TDM Rx Level
Control (V2.0
Added)
17
TDM Rx Level-
Control Level
(V2.0 Added)
2-544
Item
Input Data
0 = Disable
1 = Line Echo Cancel-
ler
2 = Acoustic Echo Can-
celler
0 ~ 6 (- 9 db ~ 9 db)
0 = - 9 db
1 = - 6 db
2 = - 3 db
:
5 = 6 db
6 = 9 db
0 = Disable
1 = TxLevelControl
mode
2 = TxAutomaticLevel-
Control mode
3 = HLC
0 ~ 16 (- 24 ~ 24 dB)
0 = - 24 dB
1 = - 21 dB
2 = - 18 dB
:
8 = 0 dB
:
14 = 18 dB
15 = 21 dB
16 = 24 dB
0 ~ 12 (- 42 ~ - 6 dBm)
0 = - 42 dBm
1 = - 39 dBm
:
7 = - 21 dBm
:
11 = - 9 dBm
12 = - 6 dBm
0 ~ 42 (- 42 ~ 0 dBm)
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
0 = Disable
1 = Enable
0 = - 42 dBm
1 = - 41 dBm
:
42 = 0 dBm
0 = Disable
1 = RX Level Control
Mode
2 = RX Automatic Level
Control Flag
0 ~ 16 (- 24 ~ 24 db)
0 = - 24 db
1 = - 21 db
2 = - 18 db
:
8 = 0 db
:
14 = 18 db
15 = 21 db
16 = 24 db
Description
Do not change the setting unless
asked to change by engineer.
Select maximum echo return loss
level.
Effective when PRG 84-31-01 = 1
Do not change the setting unless
asked to change by engineer.
Select target gain.
Effective when PRG 84-31-10 = 2
Do not change the setting unless
asked to change by engineer.
Select receive level control mode.
Do not change the setting unless
asked to change by engineer.
Select receive voice level.
Effective when PRG 84-31-16 = 1
Program 84 : Hardware Setup for VoIPDB
ISSUE 3.01
Default
Related
Program
1
2 (30 db)
84-31-01
3
8
7
84-31-10
41
1
41
0
8
84-31-16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 1100

Table of Contents