RTV-X900, RTV-X1120D, WSM
Cleaning Air Cleaner Primary Element
1. Remove the air cleaner cover and primary element.
2. Clean the primary element:
(1) When dry dust adheres to the element, blow compressed air
from the inside, turning the element. Pressure of
compressed air must be under 205 kPa (2.1 kgf/cm
30 psi).
(2) When carbon or oil adheres to the element, replace the
element with new one even if it has not been used for 1 year.
3. Replace the primary element:
Once yearly or after every sixth cleaning, whichever comes first.
NOTE
• Check to see if the evacuator valve is blocked with dust.
• Check the rubber seal. Replace if damaged.
IMPORTANT
• The air cleaner uses a dry element, never apply oil.
• Do not run the engine with filter element removed.
• Be sure to refit the cover with the arrow (on the rear of
cover) upright. If the cover is improperly fitted, evacuator
valve will not function and dust will adhere to the element.
• Do not touch the secondary element except in cases where
replacing is required.
 Evacuator Valve
Open the evacuator valve once a week under ordinary
conditions-or daily when used in a dusty place-to get rid of large
particles of dust and dirt.
(1) Secondary (Safety) Element
(2) Primary Element
(3) Rubber Seal
G-38
GENERAL
(4) Evacuator Valve
(5) Cover
9Y1210946GEG0045US0