RTV-X900, RTV-X1120D, WSM
Checking Hydraulic Lift Cable
1. Set the hydraulic lift cylinder lever (1) to neutral position.
2. Set the restricting plate (2).
3. Check that the cable is fixed to the stay, with the cable outer
section screw being set near the center "A". Also check that the
lock nuts at the cable end and the ball joint are not loose.
4. Check that the ball joint fitting nuts tightened.
5. Set the control valve lever (5) as shown in figure.
6. Then tighten the lock nuts (3) firmly.
7. Release the restricting plate (2).
8. Move the hydraulic lift cylinder lever and make sure to engage
control valve to each positions correctly. (4 position.)
(1) Hydraulic Lift Cylinder Lever
(2) Restricting Plate
(3) Lock Nut
(4) Hydraulic Lift Cable
(5) Control Valve Lever