RTV-X900, RTV-X1120D, WSM
Terminal Continuity
1. Remove the key switch from the instrument panel.
2. Measure the resistance with an ohmmeter across terminals
when the key switch is set at "OFF", "ON", "GLOW" and
"START" position.
3. If the resistance values specified below are not indicated, the
key switch is faulty.
1) Key switch is set at "OFF" position
B
terminal
terminal
B terminal
–
Infinity
ACC
Infinity
terminal
M terminal
Infinity
Infinity
G terminal
Infinity
Infinity
ST terminal
Infinity
Infinity
2) Key switch is set at "ON" position
B
terminal
terminal
B terminal
–
Continuity
ACC
Continuity
terminal
M terminal
Continuity
Continuity
G terminal
Infinity
Infinity
ST terminal
Infinity
Infinity
3) Key switch is set at "GLOW" position
B
terminal
terminal
B terminal
–
Infinity
ACC
Infinity
terminal
M terminal
Continuity
Infinity
G terminal
Continuity
Infinity
ST terminal
Infinity
Infinity
4) Key switch is set at "START" position
B
terminal
terminal
B terminal
–
Infinity
ACC
Infinity
terminal
M terminal
Continuity
Continuity
G terminal
Infinity
Infinity
ST terminal
Continuity
Infinity
(1) B Terminal
(2) ACC Terminal
(3) M Terminal
(4) G Terminal
(5) ST Terminal
8-S10
ELECTRICAL SYSTEM
ACC
M
G
terminal
terminal
Infinity
Infinity
–
Infinity
Infinity
–
Infinity
Infinity
–
Infinity
Infinity
ACC
M
G
terminal
terminal
Continuity
Infinity
–
Continuity
Infinity
–
Infinity
Infinity
–
Infinity
Infinity
ACC
M
G
terminal
terminal
Continuity
Continuity
–
Infinity
Infinity
–
Continuity
Continuity
–
Infinity
Infinity
ACC
M
G
terminal
terminal
Continuity
Infinity
–
Continuity
Infinity
–
Infinity
Infinity
–
Continuity
Continuity
(6) OFF Position
(7) ON Position
(8) GLOW Position
(9) START Position
9Y1210946ELS0010US0
ST
terminal
Infinity
Infinity
Infinity
Infinity
–
ST
terminal
Infinity
Infinity
Infinity
Infinity
–
ST
terminal
Infinity
Infinity
Infinity
Infinity
–
ST
terminal
Continuity
Infinity
Continuity
Continuity
–
KiSC issued 01, 2014 A