Symptom
Loss of Power
Transmission Oil
Over Heats
Machine Will Not
Stop in Neutral
Position
System Operates in
One Direction Only
Probable Cause
Oil level is low
Control linkage or cable damaged (speed control
cable)
Charge pressure is too low
Check and high pressure relief valve does not
move smoothly
Component parts damaged
Unload cable problem
Low transmission oil level
Radiator and oil cooler net clogged Clean
radiator net
Improper charge pressure
Control linkage is out of adjustment or sticking
Control linkage damaged
Check and high pressure relief valve damaged
Check oil level or fill
oil to proper level
Repair linkage
1. Replace oil filter
cartridge
2. Check charge
pressure
3. Inspect or flush
charge relief valve
Inspect or replace
check and high
pressure relief valve
Replace hydrostatic
transmission
assembly
1. Adjust the cable
2. Replace
Fill transmission oil
level up to proper
level
Excessive machine
load Reduce machine
load
1. Check high relief
pressure
2. Replace
transmission oil filter
cartridge
3. Replace check and
high pressure relief
valve
4. Inspect and replace
charge relief valve
Repair or replace
linkage
Adjust neutral
position
Repair or replace
linkage
Replace check and
high pressure relief
valve
2-S2
TRANSMISSION
Reference
Solution
Page
G-18
2-S32
G-26
2-S6
2-S54
2-S55
2-S19
2-S18
2-S20
G-18
G-19, G-20
2-S7
G-26
2-S55
2-S54
2-S29,
2-S34
2-S10
2-S32
2-S55