wsm RTV-X1120D Workshop Manual page 463

Table of Contents

Advertisement

RTV-X900, RTV-X1120D, WSM
Brake Lamp Switch Continuity
1. Remove the brake lamp switch leads.
2. Connect the circuit tester to the brake lamp switch leads.
3. Measure the resistance between leads.
4. If the safety switch is problem, replace it.
When switch is pushed
Resistance
When switch is released
(1) Brake Switch
Oil Temperature Alarm Switch Connector Voltage
1. Disconnect the 1P connector from the oil temperature alarm
switch (1).
2. Turn the key switch to the ON position, and measure the voltage
with a voltmeter between the connector terminal and the
chassis.
3. If no voltage is indicated, the wiring harness id faulty.
Voltage (Connector
Factory specification
terminal – Chassis)
(1) Oil Temperature Alarm Switch
Thermo Switch Continuity
1. Disconnect the 1P connector, and remove the thermo switch.
2. Using an ohmmeter, check for continuity between the switch
terminal and the chassis.
3. If
infinity
is
indicated
specifications, the switch is faulty.
Working temperature
Factory specification
(A) ON
(B) OFF
8-S21
ELECTRICAL SYSTEM
Infinity
Continuity
9Y1210946ELS0035US0
Positive voltage
9Y1210946ELS0036US0
at
temperature
over
120 to 126 °C
24.80 to 258.8 °F
(C) 120 to 126 °C (248.0 to 258.8 °F)
(D) 116 °C (240.8 °F) or more
9Y1210946ELS0037US0
KiSC issued 01, 2014 A
between

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtv-x900