wsm RTV-X1120D Workshop Manual page 477

Table of Contents

Advertisement

RTV-X900, RTV-X1120D, WSM
Brush Holder
1. Check the continuity across the brush holder and the holder
support with an ohmmeter.
2. If it conducts, replace the brush holder.
Brush holder –
Resistance
Holder support
Armature Coil
1. Check the continuity across the commutator and armature coil
core with an ohmmeter. [A]
2. If it conducts, replace the armature.
3. Check the continuity across the segments of the commutator
with an ohmmeter. [B]
4. If it does not conduct, replace the armature.
Field Coil
1. Check the continuity across the lead (1) and brush (2) with an
ohmmeter. [A]
2. If it does not conduct, replace the yoke assembly.
3. Check the continuity across the brush (2) and yoke (3) with an
ohmmeter. [B]
4. If it conducts, replace the yoke assembly.
(1) Lead
(2) Brush
8-S35
ELECTRICAL SYSTEM
Infinity
9Y1210946ELS0053US0
9Y1210946ELS0054US0
(3) Yoke
9Y1210946ELS0055US0
KiSC issued 01, 2014 A