Uid Switch Control - NEC express5800 A2010b User Manual

Hide thumbs Also See for express5800 A2010b:
Table of Contents

Advertisement

Chapter 3 Setup
8.7

UID Switch Control

You can turn on/off the UID (Unit ID) LED on the server by the virtual UID switch through the command line
interface.
Important
Turning on UID LED
Enter the following command at the command prompt.
State of the UID LED becomes same state of turning on the LED by using UID (Unit ID) switch of the server.
set /admin1/system1/led1 ActivationState=2
Turning off UID LED
Enter the following command at the command prompt.
State of the UID LED becomes same state of turning off the LED by using UID (Unit ID) switch of the server.
set /admin1/system1/led1 ActivationState=4
Confirmation of state of turning on UID LED
Enter the following command at the command prompt.
show /admin1/system1/led1
You can confirm the state of the UID LED by value of ActivateState of the "Properties" which is displayed by the
command.
ActivateState=2 : UID LED is turned on by UID switch .
ActivateState=3 : UID LED is blinking by the management software .
ActivateState=4 : UID LED is turned off by UID switch .
Tips
To perform UID Switch Control (turning on or turning off the UID LED) through
command line interface, set command is required. Accordingly, the user must have
an account as administrator.
If the server has no UID LED, the "UID Switch Control" feature works only to the virtual
UID LED of the Server Panel. See Chapter 1 (5.6.2 UID LED) for details of UID LED.
The UID LED will blink when it is controlled by Chassis Identify feature of management
software such as NEC ESMPRO Manager. The UID LED will turn on when it is
controlled by pushing the UID switch of the server or using UID switch control feature
of BMC's web server or command line interface. For actual display state of the UID
LED, blinking the UID LED is higher priority than turning on it when it is controlled at the
same time (blinking state AND turning on state).
Blinking UID LED by management software can be turned off only by management
software. Turning on UID LED by UID switch control (actual switch of the server or the
feature of BMC's web server or command line interface) can be turned off only by the
UID switch control.