UID Switch Control

You can turn on/off the UID (Unit ID) LED on the host system by the virtual UID switch
through the command line interface. This function is available only in the host system with
UID LED.
The user must have an account as administrator for UID Switch
Control (turning on or turning off the UID LED) because of using the
Notice
set command for the UID Switch Control.
Turning on UID LED
Enter the following command at the command prompt. State of the UID LED becomes same
state of turning on the LED by using UID (Unit ID) switch of the host system.
set /admin1/system1/led1 ActivateState=2
Turning off UID LED
Enter the following command at the command prompt. State of the UID LED becomes same
state of turning off the LED by using UID (Unit ID) switch of the host system.
set /admin1/system1/led1 ActivateState=4
Confirmation of state of turning on UID LED
Enter the following command at the command prompt.
show /admin1/system1/led1
You can confirm the state of the UID LED by value of ActivateState of the "Properties" which
is displayed by the command.
ActivateState=2 : UID LED state is turned on by UID switch .
ActivateState=3 : UID LED sate is blinking by the management software .
ActivateState=4 : UID LED state is turned off by UID switch .
If the UID LED is not mounted into the host system, the "UID Switch
Control" function works only to the virtual UID LED of the Server
Panel. Please refer to the User's Guide of your host system for the
description of the UID LED.
-
-