NEC express5800 A2010b User Manual page 484

Hide thumbs Also See for express5800 A2010b:
Table of Contents

Advertisement

Chapter 4 Appendix
Operation mode
FailFlow Monitor
Shutdown Monitor
POST Error Pause
Power Switch Inhibit
Fast Reboot
Clear All Faults
Security Related (Others)
「Server menu→ Power Control Configuration」
Operation mode
PSU Redundancy
Boot Related
Boot menu
Operation mode
484
Parameter
([ ]: Default setting)
[Disabled]
Enabled
1- 60 minutes
(Default: [30] minutes)
Disabled
[Enabled]
1- 60 minutes
(Default: [10] minutes)
[Disabled]
Enabled
[Disabled]
Enabled
[Disabled]
Enabled
[No]
Yes
Parameter
([ ]: Default setting)
N
N+1
[2N]
Parameter
([ ]: Default setting)
Express5800/A1040b, A2040b, A2020b, A2010b User's Guide
When
applied
At next boot
Enable or disable time monitoring from start to
end of HW fault processing due to critical failure
or start to end of OS dump collection instructed
by pressing of NMI button.
Disabled: Disables the feature.
Enabled: Enables the feature.
At next boot
Enable or disable monitoring feature of server
shutdown.
Enable: Enables the feature. When normal
shutdown fails, forcibly shuts down the server.
Disabled: Disables the feature.
At next boot
Enable or disable the feature to suppress OS
startup until user interruption if an error is
detected during POST. If set to [Disabled], does
not wait for user interruption and tries OS startup
even if an error is detected.
It is recommended to set [Disabled] because the
POST error in this case is a correctable error (the
hardware corrects an error, and the system can
continue operation).
In the system that does not permit continuous
operation even if an error is correctable, set this
item to [Enabled].
At next boot
Enable or disable the inhibit feature of the
SYSTEM POWER switch.
Disabled: Disables the feature.
Enabled: Enables the feature.
At next boot
Enable or disable the initial diagnosis of
hardware performed at system rebootup. When
set to [Disabled], it takes time for initial diagnosis
on memory and PCI before rebooting the system.
[Enabled] can be selected if shorter time for
rebootup is needed rather than fault detection.
At next boot
Use this item to clear fault information when the
failed component is replaced. See the description
of replacement procedure for failed component.
When
applied
Specify the redundancy of power supply unit.
At next boot
N: Non-redundant power supply configuration.
N+1: Uses one of the installed power supply units
as a redundant power supply unit.
2N: Uses half of the installed power supply units
as redundant power supply units.
When
applied
2. Operation Mode
Description
Description
Description