3.4 Using a Clamp-On Sensor (Option)

Connect the clamp-on sensors to the product first, and then
to the active lines to be measured. Observe the following to
avoid electric shock and short circuits.
• Clamp sensor should only be connected to the secondary
• When the clamp sensor is opened, do not allow the metal
• To prevent damage to the product and sensor, never con-
• The current input terminals of the 3169-20/21 are not insu-
Use Hioki clamp-on sensor 9660, 9661, 9667, 9669, 9694, or
9695-02/03.
3.4.1 Clamp-On Sensor Specifications
Refer to the Instruction Manual for the specific model for more
details.
9660 CLAMP ON SENSOR/ 9695-02 CLAMP ON SENSOR
Rated primary current
Output voltage
Maximum permissible input
Amplitude accuracy
Phase accuracy
Amplitude frequency
characteristics
9660
Maximum rated voltage to
earth
Measurable conductor
diameter
Operating temperature and
humidity
Option
9695-02
3.4 Using a Clamp-On Sensor (Option)
side of a breaker, so the breaker can prevent an accident if
a short circuit occurs. Connections should never be made
to the primary side of a breaker, because unrestricted cur-
rent flow could cause a serious accident if a short circuit
occurs.
part of the clamp to touch any exposed metal, or to short
between two lines, and do not use over bare conductors.
nect or disconnect a sensor while the power is on.
lated. To avoid the risk of electric shock, only use the spec-
ified optional clamp-on sensor.
100 A AC
1 mVAC/A
130 A continuous (at 45 to 66 Hz, 50
±0.3%rdg. ±0.02%f.s. (f.s.=100 A, 45 to 66 Hz)
°
Within ±1
(45 Hz to 5 kHz)
Within ±1% at 40 Hz to 5 kHz
(deviation from accuracy)
300 Vrms
15 mm max.
°
°
°
0 to 50
C (32
F to 122
(no condensation)
9219 CONNECTION CABLE (for 9695-02/03)
29
°
C)
F), 80% RH or less
1
2
3
4
5
6
7
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3169-20 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

3169-21

Table of Contents