Specifications
6.1

Signal Input Section

Item
Type
Number of slots
Maximum number of input
channels
Maximum record length
Real Time Math channels
(option)
6.2

Triggering Section

Item
Trigger mode
Selectable trigger level
range
Trigger hysteresis
Selectable trigger position
range
Selectable trigger delay
range
Selectable hold-off time
range
Manual trigger key
Simple trigger
Trigger source
Trigger slope
Time trigger
IM DL850E-03EN
Specifications
Plug-in input unit
8
16 channels per slot, 128 channels per unit (when a 16-CH voltage input module is installed in each
slot)
The maximum length when all channels are being used depends on the number of channels in
each module.
The maximum values when the entire memory is used are listed below.
Standard
250 Mpoint when 1 channel is being used. 10 Mpoint per channel when 16 channels
are being used.
/M1 option
1 Gpoint when 1 channel is being used. 50 Mpoint per channel when 16 channels
are being used.
/M2 option
2 Gpoint when 1 channel is being used. 100 Mpoint per channel when 16 channels
are being used.
The DL850E/DL850EV is equipped with 16 dedicated channels for performing computations. This
enables you to perform the following computations in real time on 16 analog input channels or
16 realtime math output channels: digital filter, basic arithmetic, basic arithmetic with coefficients,
differentiation and integration, angle of rotation, logic signal/analog waveform conversion, quartic
polynomial, rms value, power, integrated power, common logarithm, square root, cosine, sine, arc
tangent, electrical angle, knocking filter, coefficient multiplied by addition or subtraction of sources,
frequency, period, edge count, resolver, IIR filter, demodulation of the pulse width modulated signal,
reactive power, CAN ID detectionand, torque, angle difference, and 3 phase resolver. (For detailed
specifications of Real Time Math channel's math features, see section 6.5, Features.)
Real Time Math features are as follows:
• Even when the display is in roll mode, you can view the math results.
• There are no restrictions on the record length. You can specify a record length that is the same as
a normal input channel.
• Math results can be used to trigger the DL850E/DL850EV.
• Because both acquisition and computations can be performed at the same time, you can make
the waveform update period shorter than it is with normal math operations.
Specifications
Auto, Auto Level, Normal, Single, N Single, or On Start
0 ± 10 div
When measuring voltage:
When measuring temperature:
When measuring strain:
When measuring acceleration:
When measuring frequency:
0 to 100% (of the display record length; resolution: 0.1%)
0 to 10 s (resolution: 10 ns)
0 to 10 s (resolution: 10 ns)
A dedicated manual trigger key can be used.
CHn (select an input channel), EXT, LINE, or Time
Rising, falling, or rising or falling
Date (year, month, and day), time (hour and minute), and time interval (10 seconds to 24 hours)
Select from ±0.1 div, ±0.5 div, and ±1 div.
Select from ±0.5°C, ±1.0°C, and ±2.0°C.
Select from ±2.5%, ±12.5%, and ±25%.
Select from ±0.1 div, ±0.5 div, and ±1 div.
Select from ±0.01 div, ±0.5 div, and ±1 div.
1