Appendix 1 Relationship between the Time Axis Setting, Record Length, and Sample Rate
When the Record Length Is 50 kpoint, 100 kpoint, 250 kpoint, 500 kpoint, or 1 Mpoint
Record Length
50 kpoint
Time/div
Sample
Display
Rate
Record
(S/s)
Length
(Points)
1 μs
10 M
100
2 μs
10 M
200
5 μs
10 M
500
10 μs
10 M
1 k
20 μs
10 M
2 k
50 μs
10 M
5 k
100 μs
10 M
10 k
200 μs
10 M
20 k
500 μs
10 M
50 k
1 ms
5 M
50 k
2 ms
2 M
40 k
5 ms
1 M
50 k
10 ms
500 k
50 k
20 ms
200 k
40 k
50 ms
100 k
50 k
100 ms
50 k
50 k
200 ms
20 k
40 k
500 ms
10 k
50 k
1 s
5 k
50 k
2 s
2 k
40 k
3 s
1 k
30 k
4 s
1 k
40 k
5 s
1 k
50 k
6 s
500
30 k
8 s
500
40 k
10 s
500
50 k
20 s
200
40 k
30 s
100
30 k
1 min
50
30 k
2 min
20
24 k
3 min
20
36 k
4 min
20
48 k
5 min
10
30 k
6 min
10
36 k
7 min
10
42 k
8 min
10
48 k
9 min
5
27 k
10 min
5
30 k
12 min
5
36 k
15 min
5
45 k
30 min
1 h
2 h
3 h
4 h
5 h
When the time axis setting is 100 ms or greater (the settings surrounded by bold lines) and the trigger mode is Auto or Auto Level,
waveforms are displayed in roll mode.
IM DL850E-03EN
100 kpoint
250 kpoint
Sample
Display
Sample
Rate
Record
Rate
(S/s)
Length
(S/s)
(Points)
10 M
100
10 M
10 M
200
10 M
10 M
500
10 M
10 M
1 k
10 M
10 M
2 k
10 M
10 M
5 k
10 M
10 M
10 k
10 M
10 M
20 k
10 M
10 M
50 k
10 M
10 M
100 k
10 M
5 M
100 k
10 M
2 M
100 k
5 M
1 M
100 k
2 M
500 k
100 k
1 M
200 k
100 k
500 k
100 k
100 k
200 k
50 k
100 k
100 k
20 k
100 k
50 k
10 k
100 k
20 k
5 k
100 k
10 k
2 k
60 k
5 k
2 k
80 k
5 k
2 k
100 k
5 k
1 k
60 k
2 k
1 k
80 k
2 k
1 k
100 k
2 k
500
100 k
1 k
200
60 k
500
100
60 k
200
50
60 k
200
50
90 k
100
20
48 k
100
20
60 k
50
20
72 k
50
20
84 k
50
20
96 k
50
10
54 k
20
10
60 k
20
10
72 k
20
10
90 k
20
5
90 k
10
5
500 kpoint
Display
Sample
Display
Record
Rate
Record
Length
(S/s)
Length
(Points)
(Points)
100
10 M
100
200
10 M
200
500
10 M
500
1 k
10 M
1 k
2 k
10 M
2 k
5 k
10 M
5 k
10 k
10 M
10 k
20 k
10 M
20 k
50 k
10 M
50 k
100 k
10 M
100 k
200 k
10 M
200 k
250 k
10 M
500 k
200 k
5 M
500 k
200 k
2 M
400 k
250 k
1 M
500 k
200 k
500 k
500 k
200 k
200 k
400 k
250 k
100 k
500 k
200 k
50 k
500 k
200 k
20 k
400 k
150 k
10 k
300 k
200 k
10 k
400 k
250 k
10 k
500 k
120 k
5 k
300 k
160 k
5 k
400 k
200 k
5 k
500 k
200 k
2 k
400 k
150 k
1 k
300 k
120 k
500
300 k
240 k
200
240 k
180 k
200
360 k
240 k
200
480 k
150 k
100
300 k
180 k
100
360 k
210 k
100
420 k
240 k
100
480 k
108 k
50
270 k
120 k
50
300 k
144 k
50
360 k
180 k
50
450 k
180 k
20
360 k
180 K
10
360 k
5
360 k
1 Mpoint
Sample
Display
Rate
Record
(S/s)
Length
(Points)
10 M
100
10 M
200
10 M
500
10 M
1 k
10 M
2 k
10 M
5 k
10 M
10 k
10 M
20 k
10 M
50 k
10 M
100 k
10 M
200 k
10 M
500 k
10 M
1 M
5 M
1 M
2 M
1 M
1 M
1 M
500 k
1 M
200 k
1 M
100 k
1 M
50 k
1 M
App
20 k
600 k
20 k
800 k
20 k
1 M
10 k
600 k
Index
10 k
800 k
10 k
1 M
5 k
1 M
2 k
600 k
1 k
600 k
500
600 k
500
900 k
200
480 k
200
600 k
200
720 k
200
840 k
200
960 k
100
540 k
100
600 k
100
720 k
100
900 k
50
900 k
20
720 k
10
720 k
5
540 k
5
720 k
5
900 k