Table 28: Global Policy Parameters: Contact List - Grandstream Networks UCM6102 User Manual

1ghz arm cortex a8 application processor, 512mb ddr ram, 4gb nand flash
Hide thumbs Also See for UCM6102:
Table of Contents

Advertisement

LDAP Phonebook
Source
Address
Port
Base DN
User Name
Password
Number Filter
Name Filter
Version
Name Attribute
Number Attribute
Display Name
Max Hits
Search Timeout
Firmware Version 1.0.9.26

Table 28: Global Policy Parameters: Contact List

Select "Manual" or "PBX" as the LDAP configuration source.
If "Manual" is selected, the LDAP configuration below will be applied
to the SIP end device.
If "PBX" is selected, the LDAP configuration built-in from UCM6100
web UI->Settings->LDAP Server will be applied.
Configure the IP address or DNS name of the LDAP server.
Configure the LDAP server port. The default value is 389.
This is the location in the directory where the search is requested to
begin. Example:
dc=grandstream, dc=com
ou=Boston, dc=grandstream, dc=com
Configure the bind "Username" for querying LDAP servers. The field can
be left blank if the LDAP server allows anonymous binds.
Configure the bind "Password" for querying LDAP servers. The field can
be left blank if the LDAP server allows anonymous binds.
Configure the filter used for number lookups. Please refer to user manual
for more details.
Configure the filter used for name lookups. Please refer to user manual
for more details.
Select the protocol version for the phone to send the bind requests. The
default value is 3.
Specify the "name" attributes of each record which are returned in the
LDAP search result. Example:
gn
cn sn description
Specify the "number" attributes of each record which are returned in the
LDAP search result. Example:
telephoneNumber
telephoneNumber Mobile
Configure the entry information to be shown on phone's LCD. Up to 3
fields can be displayed. Example:
%cn %sn %telephoneNumber
Specify the maximum number of results to be returned by the LDAP
server. Valid range is 1 to 3000. The default value is 50.
Specify the interval (in seconds) for the server to process the request and
client waits for server to return. Valid range is 0 to 180. The default value
UCM6100 Series IP PBX User Manual
Page 99 of 305

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Ucm6104Ucm6108Ucm6116

Table of Contents