Callback is mainly designed for users who often use their mobile phones to make long distance or
international calls which may have high service charges. The callback feature provides an economic
solution for reduce the cost from this.
The callback feature works as follows:
1. Configure a new callback on the UCM6100.
2. On the UCM6100, configure destination of the inbound route for analog trunk to callback.
3. Save and apply the settings.
4. The user calls the PSTN number of the UCM6100 using the mobile phone, which goes to callback
destination as specified in the inbound route.
5. Once the user hears the ringback tone from the mobile phone, hang up the call on the mobile phone.
6. The UCM6100 will call back the user.
7. The user answers the call.
8. The call will be sent to DISA or IVR which directs the user to dial the destination number.
9. The user will be connected to the destination number.
In this way, the calls are placed and connected through trunks on the UCM6100 instead of to the mobile
phone directly. Therefore, the user will not be charged on mobile phone services for long distance or
international calls.
To configure callback on the UCM6100, go to web GUI->PBX->Call Features->Callback page and click
on
Name
CallerID Pattern
Outbound Prepend
Firmware Version 1.0.9.26

CALLBACK FEATURE

. Configuration parameters are listed in the following table.

Table 73: Callback Configuration Parameters

Configure a name to identify the Callback.
Configure the pattern of the callers allowed to use this callback. The caller
who places the inbound call needs to have the callerID match this pattern
so that the caller can get callback after hanging up the call.
Note:
If leaving as blank, all numbers are allowed to use this callback.
Configure the prepend digits to be added at before dialing the outside
number. The number with prepended digits will be used to match the
outbound route. '-' is the connection character which will be ignored.