7562
SCANNER TESTS
Scanner Calibration Reset
This option resets the scanner calibration values to factory default settings. This should be done after you
replace the flatbed scanner unit.
Note: Be sure the scanner glass and backing material are clean before performing this test.
ASIC Test
This test initiates a scan of the scanner ASIC memory. This is a pass/fail test.
X
Press Stop (
) to clear the results message from the screen.
Feed Test
This test performs a continuous feed test of either the flatbed scanner or ADF without producing any printed
output or incrementing any of the scanner-related counters.
For an ADF test, select a paper size. The ADF then performs a duplex scan using the chosen paper size
settings. For a flatbed test, the scanner traverses the entire length of the flatbed.
X
Press Stop (
) to end the test.
Sensor Test
This test checks each scanner-related sensor and returns "Closed" or "Open" for each.
Sensor (ADF document set)—"Closed" means paper is not present in the ADF.
Sensor (ADF closed interlock)—"Closed" means the scanner lid is closed.
Sensor (FB scanner HP)—"Closed" means the carriage is not positioned over the home sensor.
Sensor (ADF sheet through)—"Closed" means paper is not positioned over the home sensor.
Sensor (ADF top door interlock)—"Closed" means the ADF top door is closed.
Sensor (ADF media exit sensor)—"Closed" means paper is not positioned over the exit sensor.
Sensor (ADF lower door interlock)—"Closed" means the lower door interlock is operating.
Sensor (ADF 1st scan)—"Closed" means paper is not present above this sensor.
Sensor (ADF 2nd scan)—"Closed" means paper is not present above this sensor.
Sensor (FB length 1)—"Closed" means Executive or longer paper is not present on the flatbed.
Sensor (FB length 2)—"Closed" means Letter paper is not on the flatbed, or the scanner lid is open.
Sensor (FB length 3)—"Closed" means Legal paper is not on the flatbed, or the scanner lid is open.
Sensor (ADF long media)—"Closed" means paper is not in the ADF or not over the bin sensor.
Sensor (ADF Width 1)—"Closed" means paper is not in the ADF, or the edge guide is set to Executive.
Sensor (ADF Width 2)—"Closed" means paper is not in the ADF, or the edge guide is set to Executive.
Sensor (ADF Width 3)—"Closed" means paper is not in the ADF, or the edge guide is set to Statement.
Sensor (ADF Width 4)—"Closed" means paper is not in the ADF, or the edge guide is set to Statement
ADF Magnification
Use this menu to adjust the ADF magnification from -99 to 100. The default setting is 0.
EXIT DIAGS
Select EXIT DIAGS to exit the Diagnostics menu and return to normal mode.
3-26
Service Manual