Door Box /External Page Relay Contacts; Connecting A Contact Relay Device To A Door Box/External Page; Relay - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
6.2
6 - 18

Door Box /External Page Relay Contacts

6.2.1

Connecting a Contact Relay Device to a Door Box/External Page

Relay

To connect a dry contact relay device to a Door Box/External Page
Relay:
To connect to the CD-CP00:
1.
Connect an RCA line from the CN8 or CN9 connector on the
CD-CP00 to the appropriate location on the extension cross-
connect block.
2.
Connect the two-conductor station cable from the
cross-connect block to the external relay.
3.
Install bridging clips as required.
OR
1.
To connect to the PGD(2)-U10 ADP:
Make sure the jumper in the PGD(2)-U10 ADP for the channel
is set correctly. (Refer to Figure 6-4
Settings
2.
If a line cord was not previously connected to the PGD(2)-U10
ADP, complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U10 ADP. For each
module, run one-pair 24 AWG station cable from the
cross-connect block to a modular jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular
jack. Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1
connector on the PGD(2)-U10 ADP.
7.
Connect the two-conductor station cable from the CN5
connectors in the PGD(2)-U10 ADP to the external relay.
on page 6-4).
Installing SV8100 Optional Equipment
UNIVERGE SV8100
PGD(2)-U10 ADP Jumper

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents