Issue 5.0
Figure 6-22 NEC Terminal Connection to an IEEE 802.3af PoE Switch
6 - 32
3.
Connect the NEC VoIP telephone to the TEL connector on the
ILPA-R adapter with the LAN cable provided with the adapter.
If a customer-provided cable is used, the total length from
the switch to the telephone should be less than 328 feet.
The adapter can be positioned either closer to the keyset
or switch – it does not matter.
4.
Connect a cross-over LAN cable to the LAN connector on the
ILPA-R adapter. Plug the opposite end into the switch which is
to provide power to the telephone. Refer to
Terminal Connection to an IEEE 802.3af PoE
If a straight-through cable is used, NIC Auto Detection
must be enabled in Programs 10-12-05 (CD-CP00), 84-
05-02 (VOIPU) or 85-01-03 (SHUBU).
UNIVERGE SV8100
Figure 6-22 NEC
Switch.