NEC UNIVERGE SV8100 System Hardware Manual page 220

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 5.0
4 - 72
The PZ-4COTE consumes four trunk ports ranging between ports
001~200. The CN2 connector provides connection to four analog
trunk ports, which are polarity sensitive (tip-to-tip, ring-to-ring).
The power failure circuits (CN3), however, are not polarity sensitive.
The trunk ports are polarity sensitive. Be
careful when wiring the trunks.
When connecting the RJ-61 cable to the
PZ-4COTE blade, note the position of the
Power Failure connector (CN3). Do not
confuse this connector as the trunk connector
(CN2).
Do not wire an RJ-11 directly to the
CD-4COTA interface. Use the appropriate
RJ-61 wiring when connecting to the
CD-4COTA.
Table 4-36 PZ-4COTE Maximum Upgrade Capacities
maximum capacities for the ESIU blades when they are upgraded.
Table 4-36 PZ-4COTE Maximum Upgrade Capacities
19" Chassis
19" Chassis
with CPU
without CPU
5
19" Chassis
x4
6
23
Installing the SV8100 Blades
UNIVERGE SV8100
provides the
Networked
Chassis
32

Hide quick links: