Installation; Led Indications - NEC UNIVERGE SV8100 System Hardware Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
LED Indication
Live LED
Busy LED
(Green)
(Red)
On
On
Flash (1s)
On
Flash (1s)
On
Flash
(100ms)
Off
System Hardware Manual
4.3.2

Installation

Install the CD-4LCA
slot.
If the PZ-4LCA/PZ-8LCE is used, install this prior to inserting the CD-8LCA
.
into the chassis
4.3.3

LED Indications

LED indications for the CD-4LCA
CD-4LCA/CD-8LCA LED
associated function and LED and Operational status. Refer to
Figure 4-19 CD-4LCA Blade on page 4-52
Blade on page 4-53
Table 4-26 CD-4LCA/CD-8LCA LED Indications
Operation Status
System Initializing
The assignment of the unit is refused.
Trouble found during self-diagnostics.
A Channel is busy (use
Normal
another from CH1 ~ CHx).
Operation
All channels are idle.
When connecting a fax machine or analog
modem, make sure to set Program 15-03-03 to
1 (special terminal) to avoid communication
problems.
The SLIU and SLIDB are categorized as
TNV2. With this designation, off-premise
wiring is not acceptable. Any cabling to the
SLIU blade must be within the building – no
outside cabling is permitted.
Branch connection is not acceptable.
/
CD-8LCA blade into any available universal
CD-8LCA are listed in
/
Indications. Each LED is listed with its
for the location of the LEDs on the blades.
Issue 5.0
Table 4-26
and
Figure 4-20 CD-8LCA
Remarks
When you exceed the system
capacity.
When the main software
version is not matched.
4 - 55