Memory Initialization
Switching from the
System Menu to the RUN
Mode
Reference:
6-4
Memory Initialization
Reference:
6-4-1
Clearing Screen Data
Example:
Displaying the MAINTENANCE MODE MENU screen by pressing Mainte-
nance Mode in the System Menu.
Ver 4.12
Return to the RUN mode by selecting Quit in the System Menu and other
menus.
Unlike previous PT models, the NT631/NT631C does not return to the RUN
mode automatically if no operations are performed.
The NT631/NT631C has the following initialization functions. Use them as
necessary.
• Clearing screen data
• Initializing memory tables
• Initializing memory switches
• Initializing display history record data
• Initializing alarm history record data
• Initializing recipe tables
If writing to the screen data memory has been disabled by the System Setting
setting in the System Installer mode, memory initialization is not possible.
Use this function if the screen data has been corrupted and the NT631/
NT631C cannot be started up correctly.
This operation clears (initializes) only the screen data and contents of the cal-
culation tables. The memory switch settings and display history/alarm history
record data are retained.
Press Maintenance Mode.
page 135
page 141
page 143
page 137
page 138
page 140
Section 6-4
135