Handling Of Service Tools; Manifold Gauge Set - wsm ME8200 Workshop Manual

Table of Contents

Advertisement

ME8200, ME9000, WSM
(Reference)
Quantity (Total)
Condenser
Evaporator
Receiver
*PAG : Polyalkyleneglycol (Synthetic oil)

[1] HANDLING OF SERVICE TOOLS

(1) Manifold Gauge Set

Quantity (Total)
20 cc
0.021 U.S.qts
0.018 Imp.qts
20 cc
0.021 U.S.qts
0.018 Imp.qts
10 cc
0.011 U.S.qts
0.009 Imp.qts
The hand valves on the manifold gauge set are used to open and
close the valve. The hand valve inscribed LO is for the low pressure
side valve (3) and HI is for the high pressure side valve (4). By
opening or closing the high and low pressure hand valves, the
following circuits are established.
(1) LO Pressure Gauge
(2) HI Pressure Gauge
(3) LO Pressure Side Valve
When LO Pressure Side Valve and HI Pressure Side Valve
are Closed
Two circuits are established.
Port (C) → LO pressure gauge (1)
Port (A) → HI pressure gauge (2)
NOTE
• Schrader valve (D) must be opened.
When LO Valve is Opened and HI Valve is Closed
Two circuits are established.
Port (C) → LO pressure gauge (1)
Port (A) → HI pressure gauge (2)
NOTE
• Schrader valve (D) must be opened.
Brand Name
ND-OIL 8 <PAG* oil>
→ Port (B)
→ Port (D)
10-S10
(4) HI Pressure Side Valve
(5) Schrader Valve
W1013107
W1013376
W1013454
KiSC issued 03, 2007 A