wsm ME8200 Workshop Manual page 479

Table of Contents

Advertisement

ME8200, ME9000, WSM
Air Cleaner Sensor Panel Board and Wiring Harness
1. Disconnect the leads from the air cleaner sensor (1) after turning
the main switch OFF.
2. Turn the main switch ON and connect a jumper lead between the
leads.
3. If the air cleaner clogged lamp does not light, the panel board
circuit or wiring harness is faulty.
(1) Air Cleaner Sensor
Air Cleaner Sensor Continuity
1. Disconnect the leads from the air cleaner sensor (1) after turning
the main switch OFF.
2. Measure the resistance with an ohmmeter across the air cleaner
sensor terminals.
3. If infinity is not indicated, the sensor is faulty.
Resistance (Across
In normal state
sensor terminals)
(1) Air Cleaner Sensor
9-S38
ELECTRICAL SYSTEM
W1050130
Infinity
W1052230
KiSC issued 03, 2007 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me9000

Table of Contents