Stopping System; Checking - wsm ME8200 Workshop Manual

Table of Contents

Advertisement

ME8200, ME9000, WSM

[3] STOPPING SYSTEM

(1) Checking

Field Coil
1. Check the continuity across the lead (1) and brush (2) with an
ohmmeter.
2. If it does not conduct, replace the yoke assembly.
3. Check the continuity across the brush (2) and yoke (3) with an
ohmmeter.
4. If it conducts, replace the yoke assembly.
Lead (1) – Brush (2)
Resistance
Brush (2) – Yoke (3)
(1) Lead
(2) Brush
Key Stop Relay
1. Refer to the PTO relay checking for STARTING SYSTEM. (See
page 9-S17.)
(1) Key Stop Relay
9-S24
ELECTRICAL SYSTEM
0 Ω
Infinity
(3) Yoke
W1018015
A : ROPS Type
B : CABIN Type
W1019461
KiSC issued 03, 2007 A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Me9000

Table of Contents