Figure 10
Remote Mini-carrier Interface cabling
Power requirement
The power requirement for both the LMI and RMI is 1 amp.
Environmental requirements
The following sections describe the environmental, regulatory, and
reliability capabilities of the LMI, LMX, and RMI circuit packs.
Operating and storage considerations
The LMI, RMI, and LMX circuit packs can withstand the following
environmental conditions without any performance degradation or damage.
In this section, the phrase "short term" means 72 consecutive hours with a
maximum of 15 days per year. The temperatures are for the environment
of the pack, not the total system.
Operating temperature:
Normal: 0ûC to +65ûC 0
Short Term: 0ûC to +70ûC
Operating relative humidity:
Normal: 10% to 95% (non-condensing)
Short Term: 5% to 95% (non-condensing)
Nortel Communication Server 1000
Mini-Carrier Remote Fundamentals
NN43001-557 04.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
Environmental requirements 43