HID FARGO HDP5000 User Manual page 61

Hide thumbs Also See for FARGO HDP5000:
Table of Contents

Advertisement

Page 4-15
Setting
Lamination Card Backup
Lamination Card Length
Lamination Fan Speed
Lamination Peel Off Delay
Warming Time Delay
Enable Ribbon and Film
Saving
Input Hopper Home Offset
Input Hopper Mag Offset
Transfer Image Length
Transfer Cooling Delay
Ribbon Factory Take-up
Ribbon Factory Supply
February 2016
Description
This option changes the distance a card backs up after lamination pressure is
first applied.
This option dictates card length and should not be adjusted.
This option adjust the fan speed level to replicate printer fan speed control.
• 0 = 100%
• 1 = 75%
• 2 =50%
• 3 = 25%
This option adjust the delay between lamination stage and peel off stage.
The setting adjusts how many additional minutes the printer will wait after
the transfer roller reaches temperature before beginning transfer.
The range is 0 to 20 minutes.
This setting enables power up ribbon/film savings.
When enabled, the ribbon and film will not skip to a new set of panels after a
power up.
Cover open/close behavior is unaffected, so upon a cover close, the ribbon
and film will skip a set of panels.
Settings are:
• Disabled (0) (default)
• Enabled (1)
This setting adjusts the position of the shuttle when in the home position.
The range is 0 to 30.
The larger the number the closer to the front of the printer the shuttle will be
placed. The printer must be rebooted for this setting to take effect.
This setting adjusts the position of the shuttle when in the mag position.
The range is -20 to 20.
The larger then number the closer to the front of the printer the shuttle will
be placed. The printer must be rebooted for this setting to take effect.
This setting adjusts the length of the image on the card during transfer.
The range is -10 to +10.
The larger the number, the longer the image.
This setting adjusts the delay (in seconds) before transferring to the second
side of the card.
The range is 0 to 180. The larger the number, the longer the delay in seconds.
This setting corrects motor speed variation of the ribbon take-up motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
This setting corrects for motor speed variation of the ribbon supply motor.
The range is -20 to +20.
The larger the value the faster the motor goes.
Note: This is a factory setting, the user should never adjust this.
ToolBox
L000950, Version: 4.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fargo hdp5600Fargo hdpii plus

Table of Contents