16-Bit Timer/Event Counter Operating Precautions; Bit Timer Register Start Timing; Timings After Change Of Compare Register During Timer Count Operation - NEC PD78056F User Manual

Pd78058f series; pd78058fy series 8-bit single-chip microcontrollers
Table of Contents

Advertisement

8.6 16-Bit Timer/Event Counter Operating Precautions

(1) Timer start errors
An error with a maximum of one clock may occur concerning the time required for a match signal to be
generated after timer start. This is because the 16-bit timer register (TM0) is started asynchronously with the
count pulse.
Count Pulse
TM0 Count Value
(2) 16-bit compare register setting
Set a value other than 0000H to the 16-bit capture/compare register 00 (CR00).
Thus, when using the 16-bit capture/compare register as event counter, one-pulse count operation cannot
be carried out.
(3) Operation after compare register change during timer count operation
If the value after the 16-bit capture/compare register (CR00) is changed is smaller than that of the 16-bit timer
register (TM0), TM0 continues counting, overflows and then restarts counting from 0. Thus, if the value (M)
after CR00 change is smaller than that (N) before change, it is necessary to restart the timer after changing
CR00.
Figure 8-36. Timings After Change of Compare Register during Timer Count Operation
Count Pulse
CR00
N
TM0 Count Value
X-1
Remark N > X > M
208
CHAPTER 8 16-BIT TIMER/EVENT COUNTER
Figure 8-35. 16-Bit Timer Register Start Timing
0000H
0001H
Timer Start
X
0002H
0003H
M
FFFFH
0000H
0004H
0001H
0002H

Advertisement

Table of Contents