2GR-FE STARTING – STARTER RELAY
STARTER RELAY
ON-VEHICLE INSPECTION
1.
INSPECT STARTER RELAY ASSEMBLY
(a) Using an ohmmeter, measure the resistance
between each terminal.
Standard resistance
Tester Connection
E034090E03
If the result is not as specified, replace the starter
relay assembly.
Below 1 Ω (when battery voltage is
3 - 5
applied to terminals 1 and 2)
ST–149
Specified Condition
10 kΩ or higher
ST