Chapter 11 - V24-V25 Commands; Fixed Dte Rate +Ipr; Dte-Dce Character Framing +Icf - Multitech CDMA Wireless Modem Reference Manual

Multi-tech systems cdma wireless modem reference guide
Hide thumbs Also See for CDMA Wireless Modem:
Table of Contents

Advertisement

C
11 – V.24-V.25 C
HAPTER
Refer to ITU-T Recommendation V.25 per specification for more details on the following commands.

Fixed DTE Rate +IPR

Description:
This command specifies the data rate at which the DCE will accept commands.
Syntax:
Command syntax: AT+IPR
Command
AT+IPR?
Note: Read syntax.
AT+IPR=?
Note: List of supported <rate> values,[(list
of fixed-only <rate> values)]
AT+IPR=38400
Note: Disable autobaud and set rate to
38400 bps
AT+IPR=0
Note: Enable autobaud
(*) the first set of values indicates the range of auto-detectable speeds. The second set of
values indicates all possible speeds that can be used by the DCE. The DCE supports
Autobaud based on the data sent from the DTE.

DTE-DCE Character Framing +ICF

Description:
This command is used to determine the local serial port start-stop (asynchronous) character
framing that the DCE uses.
Values:
<format>
0: Autodetect (Not supported)
1: 8 Data 2 Stop (Not supported)
2: 8 Data 1 Parity 1 Stop (Not supported)
3: 8 Data 1 Stop (Supported)
4: 7 Data 2 Stop (Not Supported)
5: 7 Data 1 Parity 1 Stop (Not Supported)
6: 7 Data 1 Stop (Not Supported)
<parity>
0: Odd (Supported)
1: Even (Supported)
2: Mark (Supported)
3: None (Supported)
Note: The Rm interface is only supported at 8 data bits, No Parity, 1 stop bit. ERROR is
returned for other formats.
Syntax:
Command syntax: AT+ICF= <format>, <parity>
Command
AT+ICF=3,3
Note: Set values.
AT+ICF?
Note: Display current settings.
AT+ICF=?
Note: Display valid parameter ranges.
Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C
OMMANDS
Possible Responses
+IPR: 9600
OK
Note: Current rate is 9600 bps
+IPR: (0,1200,2400,4800,9600,19200), (45,50,75,
110,150,300,600,38400,57600,115200,230400)
OK
Note: Possible value (*)
OK
OK
Possible Responses
OK
Note: New values set
+ICF: 3,3
OK
Note: Current values
+ICF: (3-3),(0-3)
OK
Note: Possible values
Chapter 11 – V24-V25 Commands