Service Programming Example - Multitech CDMA Wireless Modem Reference Manual

Multi-tech systems cdma wireless modem reference guide
Hide thumbs Also See for CDMA Wireless Modem:
Table of Contents

Advertisement

Service Programming Example

Command
AT+WBGP=255,255,255,255
Note: Attempt to set the primary browser gateway
AT+WPDS?
Note: Get current Packet Dial String
AT+WSPC=1,000000
Note: Enter service programming code
AT+WPDS?
Note: Get current Packet Dial String
AT+WPDS="#999"
Note: Set the Packet Dial String to #999
AT+WCMT=1
Note: Commit all changes performed during this
provisioning AT session to non-volatile memory.
AT+WSPC=1,000111
Note: Enter service programming code
AT+WSPC=1,000000
Note: Enter service programming code
AT+WPDS?
Note: Get current Packet Dial String
AT+WPDS="#555"
Note: Set the Packet Dial String to #555
AT+WSCI?
Note: Read the current slot cycle index
AT+WSCI=1
Note: Set the slot cycle index
AT+WCMT=0
Note: Undo any changes performed during this
provisioning AT session.
AT+WSPC=1,000000
Note: Enter service programming code
AT+WPDS?
Note: Get current Packet Dial String
AT+WSCI?
Note: Read the current slot cycle index
AT+WMDN=8585551212
Note: Set mobile directory number to 8585551212
AT+WCMT=1
Note: Commit all changes performed during this
provisioning AT session to non-volatile memory.
Multi-Tech Systems, Inc. CDMA Wireless AT Commands - PN S000294C
Chapter 16 – Provisioning AT Commands
Response
ERROR
Note: Service Programming code not yet entered
ERROR
Note: Service Programming code not yet entered
OK
Note: Service Programming code entered properly
+WPDS: "#777"
OK
Note: Current Packet Dial String is #777
OK
OK
Note: software reset is performed
ERROR
Note: Service Programming code incorrect
OK
Note: Service Programming code entered properly
+WPDS: "#999"
OK
Note: Current Packet Dial String is #999
OK
+WSCI: 2
OK
OK
OK
Note: No software reset since this is an undo
command.
OK
Note: Service Programming code entered properly
+WPDS="#999"
OK
Note: Current Packet Dial String is #999 (changes not
committed from last write)
+WSCI: 2
OK
Note: Slot cycle index is 2 (changes not committed
from last write)
OK
OK
Note: software reset is performed
130

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mtsmc-c seriesMtmmc-c seriesMtcba-c series

Table of Contents