Wsw24 (Tad Setting 2) - Ricoh G157 Service Manual

Hide thumbs Also See for G157:
Table of Contents

Advertisement

MAINTENANCE MODE

WSW24 (TAD setting 2)

Selector
No.
1, 2
Maximum OGM recording time
Time length from CML ON to start
3, 4
of pseudo ring backtone
transmission
Attenuator for playback of
ICM/OGM to the line
5–8
(Selectable from the range of 0-
15 dB)
Selectors 1 and 2: Maximum OGM recording time
These selectors set the allowable maximum recording time for an OGM.
Selectors 3 and 4: Time length from CML ON to start of pseudo ring backtone
transmission
These selectors set the length of time from CML-ON up to the start of pseudo ring
backtone transmission.
In models with OGM facilities, the settings made by these selectors also apply to
the length of time from CML-ON up to the start of OGM transmission.
Selectors 5 through 8: Attenuator for playback of ICM/OGM to the line
Setting two or more selectors to "1" produces addition of attenuation assigned to
each selector. This setting is not limited by selector 8 on WSW23.
G157
Function
5-66
Setting and Specifications
No. 1. 2.
0 0: 15 sec.
0 1: 20 sec.
1 0: 30 sec.
1 1: 50 sec.
No. 3. 4.
0 0: 4 sec.
0 1: 3 sec.
1 0: 2 sec.
1 1: 1 sec.
No.5
0:
0 dB 1:
No.6
0:
0 dB 1:
No.7
0:
0 dB 1:
No.8
0:
0 dB 1:
8 dB
4 dB
2 dB
1 dB