Wsw31 (Function Setting 9) - Ricoh G157 Service Manual

Hide thumbs Also See for G157:
Table of Contents

Advertisement

WSW31 (Function setting 9)

Selector
No.
1
Not used.
Default reduction rate for failure
2
of automatic reduction during
recording
3
Not used.
4
(Do not disturb this selector.)
Minimum ON and OFF duration of
5
ringer signals effective in
distinctive ringing
6–8
Not used.
NOTE: Selector 5 is applicable only to the U.S.A. models.
Selector 2: Default reduction rate for failure of automatic reduction during recording
This selector sets the default reduction rate to be applied if the automatic reduction
function fails to record one-page data sent from the calling station in a single page
of the current recording paper.
If it is set to "0", the machine records one-page data at full size (100%) without
reduction; if it is set to "1", the machine records it at 70% size.
Selector 5: Minimum ON and OFF duration of ringer signals effective in distinctive
ringing
The ringer pattern consists of short and long rings, e.g., short-short-long rings. This
selector sets the minimum ON and OFF duration of ringer signals that are required
for the machine to interpret ringer signals as being ON or OFF. This is to prevent
components of a ringer pattern from being misinterpreted due to chattering in
distinctive ringing.
The machine monitors ringer signals at 10-ms intervals. If the signal is ON, the
machine counts +1; if it is OFF, it counts -1. If the counter increments up to +5 or
+13 when this selector is set to "1" (50 ms) or "0" (130 ms), respectively, the
machine interprets the current signal as being ON.
If the counter returns to zero, the machine interprets the signal as being OFF.
If the Distinctive Ring is set to OFF, this selector is not effective.
SM
Function
5-73
MAINTENANCE MODE
Setting and Specifications
0: 100%
1: 70%
0: 130 ms%
1: 90 ms
G157